The CellGard HD 481 Biological Safety Cabinet offers a safer environment for the compounding of hazardous drugs, powders, and cytotoxics through a three tiered filter system. HEPA filters under the work surface provide additional protection.

Catalog Number NU-481-500 Nominal 5 foot (1.5m) Performance Specifications NSF/ANSI 49 Personal Protection Product Protection NSF/ANSI 49 Class II, Type A2 Style of Cabinet Console Cabinet Construction Pressure Tight Design All welded stainless steel 16GA, Type 304 14GA HRS Base Diffuser for Air Supply (Metal) Non-flammable HEPA Filter Seal Type: HEPEX Seal Neoprene Neoprene Supply Filter-99.995% Eff. on 0.3 microns Exhaust Filter-99.995% Eff. on 0.3 microns Oval Prefilter-99.995% Eff. on 0.3 microns Fumigation : per NIH/NSF Procedures Yes Standard Services: One, Right Sidewall One, Right Sidewall Two, Backwall Service Coupling (3/8 inch NPT) Gas Valve/Service Coupling (3/8inch NPT) Duplex Outlet Optional Services: Gas Cocks 3/8" NPT Ultraviolet Light Up to 3 ea. Sidewall One, Backwall Cabinet Size Inches (mm): 87 7/8 (2232) / 93 7/8 Height (Fully Assembled) Min / Max Height (Minimum for Transport) Width -2384 Depth (with Control Center) And Armrest Removed 79 3/8 (2016) 66 7/8 (1699) 33 (838) Work Access Opening Inches (mm): Standard Opening Height/Optional Standard Inflow Velocity 10 (254) / 8 (203) 105 FPM (.53 m/s) Work Zone Inches (mm): Height 28 1/2 (724) Width 58 3/8 (1483) Depth measured at 10 inches (254mm) window height 26 (660) Viewing Window Inches (mm): Standard is safety plate sliding glass Fully closed to 18 (457) open Required Exhaust CFM/CMH Standard/Optional: 10(254) / 8(203) opening CFM (CMH) Canopy Variable Flow Thimble (NU-911) 451-676 (766-1149) / 365-590 (621-1003) Canopy Fixed Flow Thimble (NU-907) 531 (902) / 445 (756) Plant Duct Static Pressure Eng./Metric 0.05-0.1"/1.27-2.54mm H2O Heat Rejected, BTU, Per Hour (non-vented) 2983 (vented) 198 Electrical: Volts, AC 60 Hz U.L./U.L.-C Listed 115 +Amps: Blower/Lights (10/8 openings) Amps: Duplex 6.4 / 6.2 Rated Amps: 3 12 ft. Power Cord (one) 14 12 GA-3 Wire, 20A Crated Shipping Weight:*** Net Weight 840 lbs. /381 kg. 790 lbs. /358 kg.

Contact us via e-mail at info@ledtechno.be or by telephone +32 11 363 363 .

Delivery status: in stock

Delivery status: on order